Technical Parameters:

Voltage measurement range: DC00.0-99.9V                     Current measurement range: DC00.0-20.0A
Time measurement range: 0-99h59min                            Power measurement range: 0-999.9-2000 W
Temperature measurement range: -15 °c ~60°c                Capacity accumulation range: 0-999.99-9999.9 Ah
Energy accumulation range: 0-99999Wh-9999KWh           Voltage measurement accuracy: ± (0.5% + 2digits)
Current measurement accuracy: ± (1% + 2 digits)             Product weight: 33g  
Product size: 48mm*29mm*22mm (L*W*H)

Display Interface Instruction

①Run time
②Power display
③Data set
④Temperature display
⑤Capacity display
⑥Voltage display
⑦Current display
⑧Energy display

Button Function Instruction:

This tester has 0 and 1 two data groups; and data groups are switched by pressing the key.
When data group is the 1 group, the current capacity and energy will be stored after power off.
And the stored values will be accumulated after power on. When the data group is the 0 group,
the current capacity and energy will be stored after power off; when power on next time,
the stored capacity and energy are blinking displayed. But when the new capacity is up to 0.01Ah,
the stored capacity and energy will be covered, and the values will start over. At the two data groups,
the accumulated values can be cleared to zero by keeping pressing the key.

Zero calibration operation:

With the aging of components and influence of ambient temp, there might be tiny error for the current reading,
especially when measuring low current. To calibrate it: 1, power off the meter.2, disconnect the load.
3 press and hold the front button .4, power on the meter.5, release the button when you see “AAA” on the screen.
Done

The Wiring Diagram Instruction:


①Red thin line
②Black thin line
③Yellow thin line
④Red thick line
⑤Black thick line
⑥Load

Please ensure proper wiring in strict accordance with the wiring diagram.

Using Isolated Power Supply to power the meter
The two power supplies must be isolated and don’t have any connections between them.
The voltage of the isolated power supply must be less 60V

Using system to power the meter 
The black thin wire connects nothing and you should use insulator wrap it to avoid short circuit.

Using DC-DC converter to power the meter
The black thin wire connects nothing and you should use insulator wrap it to avoid short circuit.
The DC-DC converter must be common cathode structure.

Package included:

1 x 100V/20A 7in1 OLED Multifunction Tester